Background Bacterial contamination of whole blood (WB) units can result in transfusion-transmitted infection, but the extent of the risk has not been established and may be underestimated in veterinary medicine. Objectives To detect, quantify, and identify bacterial microorganisms in 49 canine WB units during their shelf life. Animals Forty-nine healthy adult dogs. Methods Forty-nine WB units were included in the study. Immediately after collection, 8 sterile samples from the tube segment line of each unit were aseptically collected and tested for bacterial contamination on days 0, 1, 7, 14, 21, 28, 35, and 42 of storage. A qPCR assay was performed on days 0, 21, and 35 to identify and quantify any bacterial DNA. Results On bacterial culture, 47/49 blood units were negative at all time points tested, 1 unit was positive for Enterococcus spp. on days 0 and 1, and 1 was positive for Escherichia coli on day 35. On qPCR assay, 26 of 49 blood units were positive on at least 1 time point and the bacterial loads of the sequences detected (Propionobacterium spp., Corynebacterium spp., Caulobacter spp., Pseudomonas spp., Enterococcus spp., Serratia spp., and Leucobacter spp.) were <80 genome equivalents (GE)/μL. Conclusions and Clinical Importance Most of the organisms detected were common bacteria, not usually implicated in septic transfusion reactions. The very low number of GE detected constitutes an acceptable risk of bacterial contamination, indicating that WB units have a good sanitary shelf life during commercial storage.

Stored Canine Whole Blood Units: What is the Real Risk of Bacterial Contamination?

STEFANETTI, VALENTINA;
2016-01-01

Abstract

Background Bacterial contamination of whole blood (WB) units can result in transfusion-transmitted infection, but the extent of the risk has not been established and may be underestimated in veterinary medicine. Objectives To detect, quantify, and identify bacterial microorganisms in 49 canine WB units during their shelf life. Animals Forty-nine healthy adult dogs. Methods Forty-nine WB units were included in the study. Immediately after collection, 8 sterile samples from the tube segment line of each unit were aseptically collected and tested for bacterial contamination on days 0, 1, 7, 14, 21, 28, 35, and 42 of storage. A qPCR assay was performed on days 0, 21, and 35 to identify and quantify any bacterial DNA. Results On bacterial culture, 47/49 blood units were negative at all time points tested, 1 unit was positive for Enterococcus spp. on days 0 and 1, and 1 was positive for Escherichia coli on day 35. On qPCR assay, 26 of 49 blood units were positive on at least 1 time point and the bacterial loads of the sequences detected (Propionobacterium spp., Corynebacterium spp., Caulobacter spp., Pseudomonas spp., Enterococcus spp., Serratia spp., and Leucobacter spp.) were <80 genome equivalents (GE)/μL. Conclusions and Clinical Importance Most of the organisms detected were common bacteria, not usually implicated in septic transfusion reactions. The very low number of GE detected constitutes an acceptable risk of bacterial contamination, indicating that WB units have a good sanitary shelf life during commercial storage.
2016
Bacterial contamination
Blood transfusion
Canine
Stored blood units
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12078/18702
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 14
social impact