A real-time system based on artificial neural networks (ANNs) for time series prediction is proposed. For each movement the prediction errors are used both to train the ANNs and to estimate a measure of the unlikelihood of the specific gesture occurrence. The first repetition of each gesture trains the related ANNs bank and the current motion is recognized after a few successive repetitions. Neither a priori assumptions nor signal pre-processing is performed (blindness). The training is performed at the beginning and can be repeated during the running (adaptability). Each procedure is strictly physically realizable (real-time feasibility). Four gestures performed by three healthy volunteers are selected by a set of upper limb motor tasks contained in the rehabilitation scale known as Wolf motor function test (WMFT). Two accelerometers placed on the upper arm and on the forearm respectively, constitute the sensors set. Even in very challenging test settings, the proposed method shows a correct recognition rate higher than 83%.

Real-time adaptive neural predictors for upper limb gestures blind recognition

GOFFREDO, MICHELA;
2009-01-01

Abstract

A real-time system based on artificial neural networks (ANNs) for time series prediction is proposed. For each movement the prediction errors are used both to train the ANNs and to estimate a measure of the unlikelihood of the specific gesture occurrence. The first repetition of each gesture trains the related ANNs bank and the current motion is recognized after a few successive repetitions. Neither a priori assumptions nor signal pre-processing is performed (blindness). The training is performed at the beginning and can be repeated during the running (adaptability). Each procedure is strictly physically realizable (real-time feasibility). Four gestures performed by three healthy volunteers are selected by a set of upper limb motor tasks contained in the rehabilitation scale known as Wolf motor function test (WMFT). Two accelerometers placed on the upper arm and on the forearm respectively, constitute the sensors set. Even in very challenging test settings, the proposed method shows a correct recognition rate higher than 83%.
2009
Accelerometers
Gesture recognition
Neural networks
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12078/18574
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact